This machine will put the sample carrying the specified load to the specified height and let it fall naturally, so that the sample will produce shock oscillation, and check the box (package), box mouth, fixing parts, connecting parts, tie rods, The integrity of the components such as the wheel, axle, wheel frame and lock and the strength of the overall structure of the specimen.
QB/T 2921-2007, QB/T2155 and other standards.
A. Support frame: the height is not less than 1800mm;
B. Falling height: 600~1500mm, adjustable electric lift;
C. Safety device: a set of upper and lower limit protection switches, equipped with left and right drop plate protection devices;
D. Test box size: ≤900mm×900mm×1500mm (maximum);
E. Falling control: Electromagnetic clutching mode, the pitch of the falling plate is steplessly adjustable;
F. Sample fixing table: diameter 300mm, hollow ring and 45 degree triangular groove parallel;
G. Falling method: the cover falls, the edge falls, and the diagonal falls;
H. Sample volume and weight: 100kg;
I. Drop plate specifications: 50 steel, 1600mm × 1800mm × 3500mm;
2/F, Building 3, No. 3599, Yuanjiang Road, Minhang District, Shanghai
No. 1, Lane 19, Zhongyi East Road, Yucheng Town, Jinshan District
021-33321965
jifayiqi@163.com